Self-Contained Systems
Premise Control Unit
A complete intrusion detection and access control system for a single facility.
The Premise Control Unit is a complete Zero Trust physical security platform in a single enclosure: intrusion detection, access control, embedded command and control and authenticated edge devices, run from a browser. Built on the Universal Field Panel™ for new or retrofit work.
- Category
- Self-Contained Systems
- Configurations
- 1
Everything in one enclosure
The PCU combines intrusion detection, access control and embedded command and control software on PSG’s Universal Field Panel. Its HTML5 web application configures the system, manages connected devices and monitors operations, with no dedicated application server and no client software to install.
Trust at the source
Unlike systems that rely on implicit trust and end-of-line resistors, the PCU authenticates field devices, secures communications and verifies events before they reach operators, automation or AI. Paired with DESI, every connected sensor, reader and door carries a cryptographic identity.
Retrofit at your own pace
Existing wiring, sensors, readers and door hardware stay in place while a facility moves to Zero Trust on its own schedule. Originally developed for Sensitive Compartmented Information Facilities, the PCU brings the same assurance to commercial, industrial and government sites.
- Complete system in a single enclosure, no application server
- Embedded command and control, managed from any HTML5 browser
- Up to 64 DESI devices and 16 OSDP readers per EM-16 panel
- Preserves existing wiring, sensors, readers and door hardware
- TAA and NDAA compliant, manufactured in the USA
Specifications
Key specifications for the PCU gateway and expansion modules. Download the data sheet for the complete document.
| Parameter | Premise Control Unit |
|---|---|
| System | |
| Gateways per system | 1 (up to 16 expansion modules per gateway) |
| Operating system | Ubuntu Core 22.04.5 LTS |
| Communications | 2 x 1000Base Ethernet |
| Open architecture | MQTT, open API and SDK, PostgreSQL, Docker container hosting |
| Capacity | |
| DESI channels | 16 per gateway, up to 64 DESI, any mix |
| Inputs and outputs | Up to 128 sensor inputs or 64 control relays per gateway |
| Serial ports | 4 x RS-485 per gateway, two field changeable to RS-232 |
| OSDP readers | 4 per serial port |
| Security | |
| Cyber security | TPM 2.0, secure boot, secure key storage, signed firmware, RMF STIG compliant OS |
| Cryptography | FIPS 140-3 compliant TLS, FIPS-186, FIPS-198, NIST SP 800-90B, ECC-P256 |
| Physical and electrical | |
| Power input | 10 to 48 VDC |
| Power output | 12 VDC at 4 A for expansion modules and readers |
| Environmental | -40 to 70°C gateway; -40 to 85°C modules, 10 to 90% RH |
| Mounting | DIN rail TS-35 standard; wall mount optional |
| Compliance | |
| Safety | UL294, UL2610, UL62638, RoHS |
| Supply chain | Made in the USA, NDAA, TAA, BAA |
Downloads
Data sheet, brochure and specification documents for this product.
A&E resources · 3 available
Specification-ready files for this product. Download what you need without leaving the page.
Where it sits
The Premise Control Unit spans Acquisition and Control and the operations layer for one facility: the panel authenticates every device, and the embedded software gives operators their view.
- Enterprise Consumers Purdue 4 to 5
- IT and OT Operations Purdue 2 to 3
- Acquisition and ControlPremise Control Unit Purdue 1
- OT Edge Purdue 0
Questions about the Premise Control Unit?